Created on 03/17/2016
c
2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 1 of 2
MODEL
RVEB
Normally closed modulating element valve with relief function
SERIES 2 / CAPACITY: 80 L/min. / CAVITY: T-2A
Three-port normally closed modulating elements with relief provide two functions when combined with an external
orifice. The mainstage is a bypass compensator that controls a priority flow into the circuit, determined by the
external orifice. Input flow in excess of the priority flow is bypassed to tank (port 2). If the inlet (port 1) pressure
rises to the valve setting, the valve operates as a normal relief valve.
TECHNICAL DATA
Factory Pressure Settings Established at 15 L/min.
Maximum Operating Pressure 350 bar
Response Time - Typical 10 ms
Maximum Valve Leakage at 110 SUS (24 cSt) 50 cc/min.@70 bar
Adjustment - Number of Clockwise Turns to Increase Setting 5
Locknut Hex Size 15 mm
Locknut Torque 9 - 10 Nm
Seal kit - Cartridge Buna: 990-202-007
Seal kit - Cartridge Polyurethane: 990-002-002
Seal kit - Cartridge Viton: 990-202-006
(L)CONTROL
L Standard Screw Adjustment
C Tamper Resistant - Factory Set
K Handknob
W Hex Wrench Adjustment
Y Tri-Grip Handknob
(A)ADJUSTMENT RANGE
A 100 - 3000 psi (7 - 210 bar), 1000 psi
(70 bar) Standard Setting
B 50 - 1500 psi (3,5 - 105 bar), 1000 psi
(70 bar) Standard Setting
C 100 - 6000 psi (7 - 420 bar), 1000 psi
(70 bar) Standard Setting
W 100 - 4500 psi (7 - 315 bar), 1000 psi
(70 bar) Standard Setting
(N)SEAL MATERIAL
N Buna-N
V Viton
MATERIAL/COATING
Standard Material/Coating
/AP Stainless Steel, Passivated
snhy.com/RVEB
TECHNICAL FEATURES
Compensating pressure for all ranges is 120 psi (8 bar).
Explanation of the performance curve: The X axis is system pressure. The Y axis shows the pressure differential that the valve creates across the control orifice.
The curves represent various bypass flows (pump flow minus control flow). The capacity and performance of this valve is determined by the bypass flow, control
Model Code Example: RVEBLANCONFIGURATION OPTIONS
Created on 03/17/2016
c
2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 2 of 2
flow is not a factor.
W and Y controls (where applicable) can be specified with or without a special setting. When no special setting is specified, the valve is adjustable throughout its full
range using the W or Y control. When a special setting is specified, this setting represents the maximum setting of the valve.
PERFORMANCE CURVES